This standard contains requirements for carbon dioxide fire extinguishing systems to help ensure that such equipment will function as intended throughout its life.
Co2 fire suppression system for electrical panels.
Pre engineered indirect firedetec electrical cabinet fire suppression system for electrical cabinet fire protection applications using co 2 extinguishing agent with dimes digital measurement system.
The co2 fire suppression systems are effective on a wide range of flammable materials and approved for class a b and c types of fire hazards.
Local application system is used for non enclosable areas 2 or 3 dimensional hazards.
However minimum clearances from energized electrical equipment must be satisfied due because a discharge of liquid co2 can create a static discharge.
In electrical panel flooding systems automatic fire suppression equipment is little and compact.
See annex a of nfpa 12.
So it can be conveyed at the opportune place in critical moment.
The variex co2 fire suppression systems are made in such a way to provide a heavy blanket of carbon dioxide gas which reduces the oxygen level to the place where combustion cannot occur.
Carbon dioxide or co 2 is a colorless odorless electrically non conductive gas that is highly efficient as a fire suppression agent.
The system are work on flexible polymer tube based fire detection system and gas suppression system.
Our pre engineered systems kats are useful for suppressing class k fires.
Total flooding extinguishers both surface and deep seated fires by discharging gas onto the enclosed space.
Novec 1230 fm 200 and co2 gas based electrical panal fire suppression system.
Fire suppression system is a revolution in the field of electrical panel fire safety system.
Fike carbon dioxide fire protection systems use intelligent reliable and fast acting control panels to quickly sense a fire before it can cause damage to property.
It is more flexible space efficient and cost effective versus alternative mechanical or electronic systems.
For co2 systems a full discharge test is required.
This system can be useful for places where required amount of water supply might not be available.
A room integrity test is not required because nfpa 12 establishes minimum leakage rates.
Co2 system consists of a fixed supply of co2 converted through a piping network and nozzles.
With our pre engineered fire suppression systems can easily extinguish the commercial cooking fires and prevent unquantifiable damage.
So it is the best decision for guaranteeing fire security to imperative spots.
It is intended for those who purchase design install test inspect approve list operate or maintain these systems.